Riello RS 70/E MZ Instrukcja Obsługi Strona 19

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 56
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 18
19
GB
Installation
4.10 Calibration of the thermal relay
The thermal relay is used to avoid damage to the motor
owing to a strong increase in absorption or the lack of a
phase.
For the calibration, refer to the table given in electrical layout
no. 6 in Appendix A.
If the minimum value of the scale of the thermal relay is
greater than the rating absorption of the motor, protection is
still ensured. This arises when the power supply of the motor
is 400 V.
To reset, in the case of an intervention of the thermal relay,
press the button 1) of Fig. 22.
Fig. 22
2
1
D8267
4
Przeglądanie stron 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 55 56

Komentarze do niniejszej Instrukcji

Brak uwag